FireNET Plus – Analog Addressable Fire Alarm Control Panel FACP

1,020.00$1,629.00$

FireNET Plus – Analog Addressable Fire Alarm Control Panel FACP

Model: FNP-1127-R/220V
Brand: Hochiki
Origin: UK
Please click here to Download Catalogue

FireNET® Plus – ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

DESCRIPTION
The FireNET® Plus 1127 series control panel is an analog addressable fire alarm panel with build options containing 1 or 2 SLC loops, a Digital Alarm Communicator/Transmitter (DACT), and an RS-485 bus for network communication. Each SLC loop supports 127 devices of any combination (sensors or modules), and 127 analog sounder bases, for a possible total of 254 points per loop. Communication between devices is accomplished by use of standard cable (shielded or twisted pair is not required). Each panel includes a 4-amp power supply and has 2 onboard NAC circuits. The RS-485 bus provides communication to the panel network while another RS-485 bus provides communication for peripheral devices. The RS-232 interface allows the convenience of programming via a PC.

The system will support a variety of Hochiki devices such as photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity modes. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module.

The Loop Explorer Windows® Software interface provides the installer with fingertip access to installation programming and diagnostic tools. An Auto Learn feature offers the convenience for quick start applications. Add to this Hochiki’s reputation for high quality and dedicated service, and you have an exceptional product with performance and value.

STANDARD FEATURES
• Analog design using Hochiki’s advanced DCP protocol for fast communication
• Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
• Uses standard wire, no-shielded or twisted pair required on SLC loops
• Integrated digital alarm communicator (DACT) with Contact ID and SIA reporting formats
• Programmable sensitivity levels by device
• Alarm verification feature
• Automatic daily calibration & drift compensation routine
• Large 8-line x 40-character LCD display (320 char.)
• 1 or 2 loop (option)
• RS-485 bus for panel network (option)
• Built-in RS-232 interface for programming via a PC
• 3 on board programmable Form C relays rated at 1 amp at 30VDC
• 2 auxiliary power outputs, each rated 360mA at 24 VDC
• Loop Explorer Windows® configuration utility
• Auto-learn feature
• 500 network wide software zones
• Network capability of up to 64 panels (option)
• Built in help and alarm information screens
• 2 on-board Class B (style Y) NAC circuits rated at 2.3 amps each (special application) and 1.6 amps each (regulated continuous)
• Gentex, System Sensor, Wheelock, and Amseco NAC sync protocol built-in
• Automatic day/night sensitivity modes
• Fire Drill test function
• Walk test function
• Powerful & versatile Cause & Effect wizard including:
*Cause & Effect action
*Disable function configuration
*Test mode configuration
• Seismic certified

Resources and Downloads

Hochiki_FireNET-Plus_FNP.pdf Download PDF
Hochiki_FireNET_Plus_Install_Manual_V1.075.pdf Download PDF

 

Weight 9.10 kg
Dimensions 483 × 369 × 89 mm
Models

FNP-1127-R/220V for 1 Loop (127 Addresses) Not-Expandable Red, FNP-1127E-R/220V for 1 Loop (127 Addresses) Expandable Red, FNP-1127E-R/220V + FNP-1127-SLC for 2 Loops (254 Addresses) Red